A denture resin can contain residual monomer without releasing more methyl methacrylate than a negative control. And the 3D-printed material may look chemically different for reasons a single screening method cannot fully reveal.
Objectives Methacrylic acid ester-based resins for denture fabrication release residual monomers and leachable substances that may interact with oral tissues. With increasing adoption of CAD/CAM technologies, a systematic comparison of leachable substance profiles and surface characteristics across polymerization methods is needed. Materials and methods This study compared the chemical composition and profiles of leachable substances of four denture materials – autopolymerized, thermal polymerized, milled, and 3D-printed – using gas chromatography–mass spectrometry (GC–MS). Surface roughness was evaluated by confocal microscopy. Results GC–MS screening detected 24 distinct compounds in the solid specimens. Among the MMA/PMMA-based materials, methyl methacrylate content was highest in the thermally polymerized resin, followed by the autopolymerized and milled materials, and absent from the 3D-printed resin, consistent with its MMA-free formulation. MMA levels in the extracts did not exceed those of the negative control in any group. Surface roughness was comparable on the polished face (Ra ≈ 0.21–0.25 μm), consistent with SEM findings but material-dependent on the unpolished, tissue-contacting face (Ra 0.37–1.03 μm). Conclusions Both fabrication method and material formulation influence the volatile and semi-volatile extractables of denture resins. As the present GC–MS screening may not reliably capture high-molecular-weight dimethacrylates such as BisEMA and UDMA, novel CAD/CAM materials require additional, complementary toxicological evaluation. Clinical relevance The leachable substance profiles of CAD/CAM denture resins, particularly the distinct compounds detected in the 3D-printed material, underscore the need for material-specific biocompatibility data to support informed clinical material selection and patient safety.
Transcript
A denture resin can contain residual monomer without releasing more methyl methacrylate than a negative control. And the 3D-printed material may look chemically different for reasons a single screening method cannot fully reveal. Methacrylic acid ester-based resins for denture fabrication release residual monomers and leachable substances that may interact with oral tissues.
With increasing adoption of CAD/CAM technologies, a systematic comparison of leachable substance profiles and surface characteristics across polymerization methods is needed. Concerns regarding the biocompatibility of methacrylic acid ester-based materials persist due to incomplete monomer conversion during polymerization.
Residual monomers and other leachable substances can diffuse into saliva and interact with cells of the oral mucosa in vivo, potentially triggering local inflammatory responses and systemic effects. Residual monomer content varies widely depending on the polymerization method, with heat-polymerized resins generally showing lower leachability than self-curing counterparts.
CAD/CAM milled dentures are presumed to exhibit greater mechanical and chemical stability due to industrial prepolymerization under controlled conditions, while three-dimensional printed resins may exhibit lower degrees of conversion and consequently higher leachability.
The study evaluated the chemical composition and leachable substance profile of two CAD/CAM-fabricated and two conventionally processed methacrylic acid ester-based denture materials. The hypothesis was that polymerization method and material formulation shape the chemical composition of the cured material and the spectrum of leachable substances.
Two CAD/CAM-fabricated and two conventionally processed denture base resins were included in the study, using cylindrical specimens ten millimeters in diameter. Prepolymerized resin specimens were milled from prefabricated resin blanks using a computer numerical control milling unit, while photopolymerized resin specimens were fabricated by stereolithography.
After printing, the photopolymerized specimens were washed in isopropanol for fifteen minutes, dried with compressed air, and post-polymerized in glycerol heated to eighty degrees Celsius with near-ultraviolet light for sixty minutes. The autopolymerized and thermally polymerized specimens were produced from the remaining rings of the prepolymerized blanks, injected at five bar pressure, and cured in a hot water bath.
The autopolymerized resin was cured at fifty-five degrees Celsius for thirty minutes, and the thermally polymerized resin at seventy to one hundred degrees Celsius for two hours. Surface roughness was measured on both the polished and unpolished, tissue-side surfaces at three locations per specimen per surface, using five specimens per material and twenty-times magnification by confocal microscopy.
Extracts from the four material groups used fourteen specimens pooled per group in a single extraction batch, following a surface-area-to-volume ratio of three square centimeters per milliliter. The extraction volume was zero point seven eight five milliliters per specimen, based on a total cylindrical surface area of two point three five six square centimeters.
Fourteen specimens were incubated in eleven milliliters of Keratinocyte Growth Medium 2 with supplements for forty-eight hours at thirty-seven degrees Celsius to simulate clinically relevant extraction conditions. Pure Keratinocyte Growth Medium 2 with supplements served as a negative control in all subsequently performed experiments.
A semi-quantitative gas chromatography–mass spectrometry screening examined the four solid specimens and their corresponding extracts. Analysis of the solid specimens revealed a total of twenty-four distinct compounds in the total ion chromatograms. Methyl methacrylate was detected in the prepolymerized, autopolymerized, and thermally polymerized specimens, but was not detected in the photopolymerized specimens, in line with their MMA-free, dimethacrylate-based formulation.
Thermal polymerization yielded the highest methyl methacrylate content in the solid material, followed by autopolymerized and prepolymerized specimens, while photopolymerized specimens contained no detectable methyl methacrylate. Although methyl methacrylate was detected in the solid material of the thermally polymerized, prepolymerized, and autopolymerized samples, concentrations in the corresponding extracts were at or below the negative control.
In panel A, the thermally polymerized trace forms a sharp peak near five minutes, reaching the top of the relative-intensity scale, while the other material traces remain much smaller or near baseline. In panel B, the extract traces cluster closely with the blue negative-control curve, showing only a modest shared bump just after five minutes rather than a distinct dominant peak.
The study examined how polymerization method and material formulation influence residual monomer content and leachable substance profiles in four methacrylate-based denture base resins. CAD/CAM-based fabrication encompasses subtractive manufacturing, in which an industrially prepolymerized resin blank is milled into the desired prosthetic shape, and additive manufacturing.
These approaches differ from conventional polymerization in their processing conditions, base monomer systems, and degree of conversion, with direct implications for the nature and quantity of leachable substances. GC–MS analysis of the solid specimens revealed that residual monomer content varied by polymerization method.
Among the MMA/PMMA-based materials, thermal polymerization yielded the highest MMA content, followed by autopolymerized and prepolymerized specimens. GC–MS detected a broader range of substances than those declared by the manufacturers.
This discrepancy underscores the importance of independent analytical characterization as a complement to manufacturer disclosure. Fabrication method and material formulation jointly determine the residual monomer content and extractable substance profile of the tested denture base resins, rather than polymerization method acting as an isolated variable.
Among the PMMA-based materials, residual monomer content was lowest for the CAD/CAM-milled specimens and highest for the thermally polymerized specimens, yet MMA released into the extraction medium remained negligible under the tested short-term conditions for all groups.
The three-dimensional printed resin showed a distinct set of detected constituents consistent with its formulation containing Bis-EMA, UDMA, and TMPTMA; because the screening may not reliably capture Bis-EMA and UDMA, their absence should not be interpreted as evidence that they are not leachable.
Surface roughness was comparable among materials on the polished surfaces but differed on the unpolished, tissue-contacting surfaces. Fabrication method and material formulation jointly shape what remains in denture resins and what can be extracted. The short-term extracts showed negligible MMA, but novel CAD/CAM materials still need material-specific, complementary toxicological evaluation.
A derivative work by Paperi · AI-generated script, voice and captions
· pages and figures unaltered
Made with Paperi.
Drop in a research PDF — get a narrated video walkthrough like this one,
with highlights that follow the narration. Free to start.
Reyhane Narimany, Reyhaneh Faghihian, Mehdi Jafarzadeh Samani
A small device combines cooling and vibration to make a dental injection less frightening for children. But when it was tested, the reassuring sensation did not clearly reduce either pain or anxiety.A device combining cold and vibration sounds like a simple way to make dental injections easier for children. But in this randomized trial, BUZZY did not significantly reduce pain or anxiety during the injection.
Bilun Jin, Heng Chen, Peiqi Liu, Yijie Wang, Yi Guo, Chenxu Wang, Yue Jia, Rui Zou, Lin Niu
Tea is often treated as a healthy choice for your mouth. But this study found a genetic clue pointing in the opposite direction for gum disease, while finding no link with cavities.Tea is often discussed as either helpful or harmful for oral health. This study uses genetic evidence to test whether drinking more tea is actually linked to cavities, periodontitis, or tooth loss.
Ferdinando Ruiz, Pietro Venezia, Vincenzo Ronsivalle, Calogero Lacagnina, Cristina Conforte, Gaetano Isola, Rosalia Leonardi, Antonino Lo Giudice
Orthodontic treatment can move teeth, but the bone at the front of the lower jaw sets a boundary. This study asks whether that boundary naturally reshapes during the teenage years, and finds a reason not to count on it.A teenager’s mandibular symphysis may look different depending on facial growth pattern, but this study found that age and sex themselves did not significantly change its form between twelve and fifteen.